Skip to content

Prepaway Exam Dumps

Best High Pass-Rate Exam Dumps

  • HOME
  • ALL EXAMS
  • Cisco
  • SAP
  • Huawei
  • Avaya
  • IBM
  • Amazon
  • Contact
  • HOME
  • ALL EXAMS
  • Cisco
  • SAP
  • Huawei
  • Avaya
  • IBM
  • Amazon
  • Contact

Tag Archives: LEED-AP-BD-C latest real test

  1.   »  
  2. Tag Archives: LEED-AP-BD-C latest real test

Tag: LEED-AP-BD-C latest real test

LEED-AP-BD-C Dumps 2026 New USGBC LEED-AP-BD-C Exam Questions [Q182-Q204]

LEED-AP-BD-C Dumps 2026 New USGBC LEED-AP-BD-C Exam Questions [Q182-Q204]

September 12, 2026 adminLEED-AP-BD-C, USGBCLEED-AP-BD-C demo test, LEED-AP-BD-C exam syllabus, LEED-AP-BD-C Free download, LEED-AP-BD-C latest real testLeave a Comment on LEED-AP-BD-C Dumps 2026 New USGBC LEED-AP-BD-C Exam Questions [Q182-Q204]

LEED-AP-BD-C Dumps 2026 – New USGBC LEED-AP-BD-C Exam Questions

Free LEED-AP-BD-C braindumps download (LEED-AP-BD-C exam dumps Free Updated)

USGBC LEED-AP-BD-C Exam Overview:

Certification Vendor: USGBC (U.S. Green Building Council), administered by GBCI
Exam Name: LEED AP Building Design + Construction Specialty Exam
Exam Number: LEED-AP-BD-C
Exam Format: Computer-based, Multiple-choice, Scenario-based, Proctored online or at test centers
Exam Price: $250–$400 USD (specialty only: $250 member / $400 non-member; combined: $400 member / $550 non-member)
Certificate Validity Period: 2 years (requires continuing education to renew)
Passing Score: 170 (scaled score range 125–200)
Exam Duration: 120 (2 hours); combined option: 240 (4 hours)
Related Certifications: LEED Green Associate
LEED AP Interior Design + Construction
LEED AP Operations + Maintenance
LEED AP Neighborhood Development
LEED AP Homes
Available Languages: English, Arabic, Brazilian Portuguese, Chinese, French, Spanish
Real Exam Qty: 100 (85 scored, 15 unscored pretest); combined: 200
Recommended Training: Official Study Materials
LEED AP BD+C Candidate Handbook
Exam Registration: Official Registration
Sample Questions: USGBC LEED-AP-BD-C Sample Questions
Exam Way: Online proctored or in-person at Prometric test centers
Pre Condition: Active LEED Green Associate credential; or take combined exam
Official Syllabus URL: https://www.usgbc.org/credentials/leed-ap-bd-c

 

Q182. During a review of the HVAC equipment submittal, the Commissioning Authority (CxA) determined that the contractor substituted a higher efficiency piece of equipment. Which of the following is the priority for the CxA to consider?

 
 
 
 
The Owner’s Project Requirements (OPR) is a document that defines the goals, expectations, and performance criteria of the project, as established by the owner or the owner’s representative1. The OPR is one of the key deliverables of the commissioning process and serves as the basis for the design, construction, and operation of the building systems. Therefore, the priority for the Commissioning Authority (CxA) to consider when the contractor substitutes a higher efficiency piece of equipment is whether the substitution meets or exceeds the OPR. The CxA should verify that the new equipment is compatible with the OPR and does not compromise the performance, functionality, or reliability of the system. The CxA should also communicate the substitution to the owner and the design team and document the change in the commissioning plan and report.

Q183. Which of the following Building Product Disclosure and Optimization credits under the Materials and Resources category would a project team achieve by using insulation material that is cradle-to-cradle V3 Gold certified?

 
 
 
 
Detailed
Cradle-to-cradle certification (Gold level) meets the requirements for Material Ingredient Optimization under Option 2. It demonstrates the product’s compliance with advanced environmental standards, supporting the LEED focus on transparency and optimization of building materials to minimize their environmental and human health impacts.

Q184. A luxury hotel project is in the design phase and is located on a scenic waterfront. It is one point away from attaining LEED Platinum certification. The LEED AP is recommending that the team pursue Innovation Credit, Innovation, Option 3. Additional Strategies. Which of the following credits would be desirable considering the location of the project?

 
 
 
 
The LEED Platinum certification requires the project to achieve exemplary performance in at least one credit that allows it, as specified in the LEED Reference Guide1. One of the credits that meets this criterion is the Indoor Environmental Quality Credit, which focuses on providing healthy and comfortable indoor environments for occupants. The credit has two options: Quality Views and Enhanced Commissioning.
Quality Views requires the project to have windows that provide views of natural scenery or water bodies, which can enhance the well-being and satisfaction of occupants. Enhanced Commissioning requires the project to have a comprehensive commissioning plan that ensures all systems are properly installed, tested, and operated before occupancy. Both options can help reduce energy consumption, improve indoor air quality, and create a positive sensory experience for occupants.
References:
* LEED Reference Guide v4
* LEED Platinum Certification – LD Products
* LEED Accreditation | LEED Certification & Credentials Overview – GBES

Q185. Which of the following is an example of a nonroof measure for Sustainable Sites Credit, Heat Island Reduction?

 
 
 
 
A vegetated shading structure is an example of a nonroof measure for Sustainable Sites Credit, Heat Island Reduction. The heat island effect is the phenomenon of urban areas having higher air temperatures than surrounding rural areas due to the absorption and emission of heat by human-made surfaces, such as buildings, roads, and pavements. The heat island effect can have negative impacts on the environment, human health, and energy consumption. One of the strategies to reduce the heat island effect is to use nonroof measures that provide shade, reflectivity, or evapotranspiration for at least 50% of the site hardscape, such as parking lots, walkways, plazas, and courtyards1. A vegetated shading structure is a type of nonroof measure that consists of a trellis or pergola that supports climbing plants or vines that provide shade and cooling for the underlying surface. A vegetated shading structure can also enhance the aesthetic and ecological value of the site2.
The other options are not examples of nonroof measures for Sustainable Sites Credit, Heat Island Reduction.
A playground with artificial turf is not a nonroof measure, but a roof measure, as it is considered as part of the building envelope. Artificial turf is also not a compliant roof measure, as it does not meet the minimum solar reflectance index (SRI) or vegetated roof requirements1. A shade structure with a three-year aged SRI value of 0.2 is not a compliant nonroof measure, as it does not meet the minimum SRI value of 29 for nonroof surfaces1. A paving material with a three-year aged SRI value of 0.2 is also not a compliant nonroof measure, as it does not meet the minimum SRI value of 29 for nonroof surfaces1.

Q186. Location and Transportation Credit, Surrounding Density and Diverse Uses, Option 1. Surrounding Density requires project teams to exclude what type of land area from the calculations?

 
 
 
 
This option requires the project team to exclude public right-of-way areas, such as streets, sidewalks, and alleys, from the calculations of the surrounding existing density1. This option ensures that the density is measured based on the buildable land area, which is the area available for development or construction2.

Q187. Which of the following assessments is conducted prior to the completion of the schematic design and explores methods to reduce energy use within a proposed building?

 
 
 
 
A simple box energy analysis, also known as a “mass model” analysis, is performed during the early design phases, typically before the completion of the schematic design. This assessment involves creating a simplified model of the proposed building to evaluate its potential energy performance. The goal is to explore various design options and strategies that can reduce energy consumption, such as building orientation, envelope characteristics, and massing. Conducting this analysis early allows the design team to make informed decisions that enhance energy efficiency from the outset. ​

Q188. A downtown office building is unable to construct dedicated parking for its occupants. However, the building developer has partnered with a parking garage to offer discounted parking for its occupants. If the discounted parking rate is $450 per month, how much must the rate be for green vehicles for the building to receive one point for Location and Transportation Credit, Green Vehicles?

 
 
 
 
Explanation
For the building to receive one point for Location and Transportation Credit, Green Vehicles, the rate for green vehicles must be 80% less than the regular parking rate.Therefore, if the discounted parking rate is $450 per month, the rate for green vehicles must be $90 per month (20% of $450).References: LEED AP Building Design + Construction (LEED AP BD+C) V4 resources1

Q189. In the step-by-step guidance for Location and Transportation Credit, Bicycle Facilities, which of the following requirements can define a bicycle network?

 
 
 
 
According to the LEED Reference Guide for Building Design and Construction1, the Location and Transportation Credit, Bicycle Facilities, requires the project to provide short-term and long-term bicycle storage and a functional entry or bicycle storage within 200 yards of a bicycle network. The bicycle network is defined as any one of the following:
* Off-street bicycle paths or on-street bicycle lanes that are physically marked and separated from motor traffic
* Streets designed for a target speed of 25 mph (40 km/h) or less, with traffic calming features such as curb extensions, speed humps, raised crossings, narrowed traffic lanes, median islands, tight corner radii, roundabouts, or landscaping
* Streets with a legal speed limit of 25 mph (40 km/h) or less that connect to a larger bicycle network Therefore, among the given options, only slow speed roadways can define a bicycle network, as they can provide a safer and more comfortable environment for cyclists. One-way streets, bike share, and traffic lights are not sufficient to define a bicycle network, as they do not necessarily indicate the presence of bicycle paths, lanes, or low-speed streets.

Q190. Qualifying spaces for the Sustainable Sites Credit, Places of Respite must

 
 
 
 
According to the LEED AP BD+C V4 reference guide for Healthcare, places of respite must be outdoors or located in interior spaces with views of nature, and have options for shade or indirect sun for a portion of seating spaces. The other options are either incorrect or not required by the credit. Reference: LEED AP BD+C V4 reference guide for Healthcare, Places of respite

Q191. A Photovoltaic (PV) system was installed on a 35,000 ft2 (3 252 m2) project. What actions need to take place in order to meet compliance for Energy and Atmosphere Prerequisite, Fundamental Commissioning (Cx) and Verification?

 
 
 
 
Explanation
The correct answer is C, the Cx agent for the project must conduct or oversee the Cx of the PV system.
According to the LEED v4 Reference Guide for Building Design and Construction, the Energy and Atmosphere Prerequisite, Fundamental Commissioning and Verification, requires that all energy-related systems, including renewable energy systems such as PV, be commissioned by an independent commissioning agent (CxA) or a qualified member of the project team who reports to the owner. The CxA or the qualified team member must perform or oversee all commissioning activities, including developing a commissioning plan, reviewing design documents and submittals, verifying installation and performance, and preparing a commissioning report12 References: 1: LEED v4 Reference Guide for Building Design and Construction, Energy and Atmosphere Prerequisite: Fundamental Commissioning and Verification, page 562. 2: LEED v4 Reference Guide for Building Design and Construction, Glossary, page 1020.

Q192. For an emergency care facility project, which of the following credits can be achieved if the total cost of permanently installed products are 25% cradle-to-cradle V3 Gold and 25% GreenScreen List Translator?

 
 
 
 
The Materials and Resources Credit, Building Product Disclosure and Optimization, Material Ingredients, Option 2. Material Ingredient Optimization & Innovation Credit, Innovation, Exemplary Performance can be achieved if the total cost of permanently installed products are 25% cradle-to-cradle V3 Gold and 25% GreenScreen List Translator. This is because these certifications indicate that the materials used in the project have been assessed for their environmental and health impacts, contributing to the achievement of these credits.References: LEED AP Building Design + Construction (LEED AP BD+C) V4 resources 1

Q193. Which of the following activities must be prohibited within a building as a prerequisite to LEED certification?

 
 
 
 

Q194. For Indoor Environmental Quality Credit, Construction Indoor Air Quality Management Plan, which of the following items is required for credit compliance?

 
 
 
 
The Indoor Air Quality Assessment credit under LEED v4.1 BD+C rating system (Building Design and Construction) seeks to establish better quality indoor air in the building after construction and during occupancy. The credit provides two options for compliance, which cannot be combined1. Therefore, Indoor Environmental Quality test results would be required for credit compliance.

Q195. What is the minimum gross floor area required for a Building Design and Construction project to be eligible for certification?

 
 
 
 
According to the LEED minimum program requirements, the LEED project must include a minimum of 1000 square feet (93 square meters) of gross floor area for the LEED BD+C and LEED O+M rating systems1.
:
LEED V5: Building Design + Construction Guide
LEED minimum program requirements

Q196. A project design team for an elementary school project is attempting to achieve Innovation Credit, Innovation, Option 1. Innovation. Which of the following strategies would qualify?

 
 
 
 
Explanation
This strategy would qualify as an innovation credit because it is not addressed in the LEED green building rating system, and it achieves significant, measurable environmental performance by educating the students and the community about the benefits of green building. The project team would need to identify the intent, requirements, submittals, and design approach of this strategy in the Basis of Design document1. This strategy is also listed as an example of innovation in the LEED Innovation Catalog2.
References: = NC-v4.1 INc1: Innovation | LEEDuser, LEED credit library | U.S. Green Building Council

Q197. Which of the following should be analyzed when pursuing an Integrative Design Process focusing on Energy-Related Systems?

 
 
 
 
The correct answer is A, site conditions. According to the LEED v4: Building Design + Construction Guide, the Integrative Process Prerequisite, Integrative Project Planning and Design, requires the project team to perform a preliminary “simple box” energy modeling and analysis before the completion of schematic design. The purpose of this analysis is to evaluate the energy performance goals of the project and to identify and compare the energy-related design strategies. The analysis should include the following aspects1:
Site conditions, such as climate, solar orientation, shading, and natural ventilation potential Massing and orientation, such as building shape, size, and orientation, and how they affect the heating and cooling loads, daylight availability, and passive design strategies Basic envelope attributes, such as insulation levels, window-to-wall ratio, glazing properties, infiltration rates, and thermal bridging Lighting levels, such as the target illumination levels, daylighting potential, and lighting power density Plug and process loads, such as the equipment and appliances that consume electricity, and their schedules and controls Programmatic and operational parameters, such as the occupancy, operating hours, and zoning of the building Thermal comfort ranges, such as the acceptable temperature and humidity levels for the occupants HVAC system selection, such as the type, efficiency, and control of the heating, ventilation, and air conditioning system The other choices are not aspects that should be analyzed when pursuing an integrative design process focusing on energy-related systems, because:
Potable water availability is related to the water efficiency and water quality goals of the project, not the energy performance goals2.
Acoustic performance of the project is related to the indoor environmental quality and occupant comfort goals of the project, not the energy performance goals3.
Applicability of green vehicles to the project is related to the location and transportation and greenhouse gas emissions goals of the project, not the energy performance goals4.

Q198. The intent of the Sustainable Sites Prerequisite. Construction Activity Pollution Prevention is to £

 
 
 
 
Explanation
The intent of the Sustainable Sites Prerequisite. Construction Activity Pollution Prevention is to reduce pollution from construction activities by controlling soil erosion, waterway sedimentation and airborne dust generation. The LEED v4 Reference Guide for Building Design and Construction states that “construction activities can have significant negative impacts on the environment, both at the project site and beyond.
Erosion and sedimentation can degrade water quality, damage aquatic habitats, and increase flooding risks.
Airborne dust can affect air quality, human health, and visibility. Construction vehicles and equipment can generate noise, traffic, and greenhouse gas emissions”1. The project teammust implement an erosion and sedimentation control (ESC) plan that conforms to the 2012 U.S. Environmental Protection Agency Construction General Permit or local equivalent, whichever is more stringent. The ESC plan must cover all construction activity on the project site, including clearing, grading, excavating, and demolition.
References:
* LEED v4 Reference Guide for Building Design and Construction, Sustainable Sites Prerequisite:
Construction Activity Pollution Prevention, page 1151
* Construction activity pollution prevention | U.S. Green Building Council

Q199. A LEED Building Design and Construction project includes an outdoor stage for theatrical performances. In pursuit of Sustainable Sites Credit, Light Pollution Reduction the engineer has specified an LED fixture to illuminate actors on the stage while limiting light pollution. Which of the following suggestions should the LEED AP give to the project owner?

 
 
 
 
Explanation
The Sustainable Sites Credit, Light Pollution Reduction aims to minimize the adverse effects of artificial lighting on the night sky, human health, and wildlife1. However, the credit does not apply to lighting that is required for safety, security, or emergency purposes2. According to the LEED Reference Guide for Building Design and Construction, lighting for theatrical performances is considered an emergency purpose and is exempt from the credit requirements3. Therefore, the LEED AP should inform the owner that the LED fixture is exempt from Sustainable Sites Credit, Light Pollution Reduction and does not need to be modified or compared to an alternative. Enclosing the performance areas would not reduce light pollution, but rather increase energy consumption and affect the outdoor experience. Calculating the return on investment over the
20-year life of the project is irrelevant to the credit and would not help achieve it.
References:
Light Pollution Reduction
Light Pollution Reduction: Sustainable Site Credit for LEED Existing Building O+M
[LEED Reference Guide for Building Design and Construction v4], page 581

Q200. When measuring sound pressure levels in a classroom to determine compliance with the HVAC background noise requirements of LEED Building Design and Construction: Schools, Indoor Environmental Quality Prerequisite, Minimum Acoustic Performance, what testing conditions are appropriate for the classroom?

 
 
 
 
To meet the Indoor Environmental Quality (IEQ) Prerequisite: Minimum Acoustic Performance for classrooms, sound pressure level measurements should be taken under conditions that reflect typical classroom use without occupants, ensuring accuracy in assessing HVAC background noise levels. Furnished, no occupants, HVAC operating at typical level (C) is the correct testing setup, as it accounts for sound absorption by furniture but excludes ambient noise from people. This setup provides a more accurate measure of the background noise levels produced by HVAC systems, ensuring compliance with acoustic performance requirements for optimal learning environments.

Q201. A mixed-use development is located 1/2 mi. (0.80 km) from a future commuter rail line station. Which of the following pieces of information is needed when determining whether the rail line station can contribute to Location and Transportation Credit, Access to Quality Transit?

 
 
 
 
The rail line station construction completion date is needed when determining whether the rail line station can contribute to Location and Transportation Credit, Access to Quality Transit. This is because the credit requires that the transit service must be existing or planned to be in operation within two years of the project’s occupancy1. Discounted rail pass availability, connections to transfer routes, and passenger capacity are not relevant for this credit1.
Reference:
* Access to quality transit, p. 1

Q202. A tenant of a new office building will require 100 workstations per floor. Each floor will have two bathroom facilities and one conference room. How many lighting control devices with at least three lighting levels per floor are required to comply with Indoor Environmental Quality Credit, Interior Lighting, Option 1. Lighting Control?

 
 
 
 
To comply with Indoor Environmental Quality Credit, Interior Lighting, Option 1. Lighting Control, the tenant of a new office building will require 93 lighting control devices with at least three lighting levels per floor. This is because the credit requires that at least 90% of individual occupant spaces have lighting controls that enable occupants to adjust the lighting to suit their individual tasks and preferences1. The credit also requires that all shared multioccupant spaces have lighting controls that enable adjustments that meet the needs of the group1. According to the LEED BD+C Reference Guide, an individual occupant space is defined as an enclosed space or an open space that is occupied by one person and is at least 50 square feet (4.6 square meters) in area1. A shared multioccupant space is defined as an enclosed or open space that is occupied by more than one person and is at least 100 square feet (9.3 square meters) in area1.
Based on the given information, each workstation can be considered as an individual occupant space, and each bathroom facility and conference room can be considered as a shared multioccupant space. Therefore, the number of lighting control devices per floor can be calculated as follows:
For the 100 workstations, 90% of them need lighting controls, which is 90 workstations. Each workstation needs one lighting control device, so the total number of lighting control devices for the workstations is 90.
For the two bathroom facilities, each facility needs one lighting control device, so the total number of lighting control devices for the bathroom facilities is 2.
For the one conference room, one lighting control device is needed, so the total number of lighting control devices for the conference room is 1.
The total number of lighting control devices per floor is then 90 + 2 + 1 = 93.

Q203. Which strategy should be employed to improve daylighting when designing a new building?

 
 
 
 
Increase the number of skylights
Skylights are openings in the roof or ceiling that allow natural light to enter the building. They can improve daylighting by providing more uniform and diffuse illumination, reducing the need for artificial lighting, and enhancing the visual comfort and well-being of occupants. Skylights can also reduce cooling loads by minimizing solar heat gain through the roof. However, skylights must be designed carefully to avoid glare, overheating, and heat loss issues.

Q204. What are the three phases within the Integrative Process Credit, Integrative Process?

 
 
 
 
The Integrative Process credit under the LEED BD+C v4 rating system encourages the coordination of all the project team members, starting from the predesign phase, to discover unique opportunities for project design, enhanced building performance, and green features. The three phases within the Integrative Process Credit are:
Discovery phase: This involves investigating at least two energy-related and several water-related sustainable design strategies prior to the end of schematic design1.
Design and Construction (implementation) phase: This requires the project teams to turn their findings into reality2.
Occupance, Operations, and Performance Feedback phase: This phase involves the evaluation of the implemented strategies and their effectiveness3.
:
LEED Integrative Process Credit Explained – Projectific, Inc.
LEED AP BD+C v4 – Integrative Process Flashcards | Quizlet
Achieving theLEED V5Integrative Process Credit – SketchUp

Loading ... Loading …

Loading

USGBC LEED-AP-BD-C Exam Syllabus Topics:

Topic Details
Topic 1
  • Indoor Environmental Quality: This domain measures the skills of LEED Green Associates in creating healthy indoor environments. It emphasizes the importance of maintaining adequate ventilation levels through both natural and mechanical means. Additionally, candidates will be assessed on topics such as tobacco smoke control measures.
Topic 2
  • Sustainable Sites: It covers site assessment and planning that involves evaluating various site characteristics, such as topography, hydrology, climate, vegetation, and soil conditions. It also covers assessing a site’s potential as a resource for energy flows while addressing construction activity pollution prevention measures.
Topic 3
  • Water Efficiency: This topic measures the skills of LEED Green Associates in optimizing water use in building projects. It explores strategies for reducing outdoor water use through efficient irrigation practices, including landscape water requirements and irrigation systems. It also covers using native and adaptive plant species to minimize irrigation demands.
Topic 4
  • Project Surroundings and Public Outreach: LEED Green Associates learn about promoting sustainable practices, regional design considerations that incorporate green construction measures, cultural awareness issues related to historic or heritage impacts, and ensuring that sustainability efforts are respectful of local values.
Topic 5
  • Integrative Strategies: It emphasizes the importance of an integrative process. The topic also covers their knowledge about the value of teamwork in developing integrative green strategies and how they can collaborate throughout different project phases.
Topic 6
  • LEED Process: This topic tests the skills of LEED Green Associates involved in green building initiatives. It focuses on various methods to achieve LEED goals, such as developing credit interpretation rulings and utilizing Regional Priority Credits to explore synergies within the LEED system.

 

Verified LEED-AP-BD-C dumps Q&As – Pass Guarantee Exam Dumps Test Engine: https://www.prepawayexam.com/USGBC/braindumps.LEED-AP-BD-C.ete.file.html

Read More

Recent Posts

  • UPDATED [Oct 01, 2026] Pass Splunk Certified Cybersecurity Defense Analyst Exam with Latest Questions [Q46-Q60]
  • Pass Palo Alto Networks SecOps-Generalist Actual Free Exam Q&As Updated Dump Oct 01, 2026 [Q87-Q104]
  • [2026] Earn Quick And Easy Success With ESDP_2025 Dumps [Q55-Q76]
  • The Best AB-730 Exam Study Material and Preparation Test Question Dumps [Q29-Q49]
  • [Sep-2026] Latest Fitness NCSF-CPT Certification Practice Test Questions [Q14-Q34]

Archives

  • October 2026
  • September 2026
  • August 2026
  • July 2026
  • May 2026
  • April 2026
  • March 2026
  • February 2026
  • January 2026
  • December 2025
  • November 2025
  • October 2025
  • September 2025
  • August 2025
  • July 2025
  • April 2025
  • March 2025
  • February 2025
  • January 2025
  • December 2024
  • November 2024
  • October 2024
  • September 2024
  • August 2024
  • July 2024
  • June 2024
  • May 2024
  • March 2024
  • February 2024
  • January 2024
  • December 2023
  • November 2023
  • October 2023
  • September 2023
  • August 2023
  • July 2023
  • June 2023
  • May 2023
  • April 2023
  • March 2023
  • February 2023
  • January 2023
  • December 2022
  • November 2022
  • October 2022
  • September 2022
  • August 2022
  • July 2022
  • June 2022
  • May 2022
  • April 2022

Categories

  • A10 Networks
  • AACE International
  • AAPC
  • ACAMS
  • Adobe
  • AHIMA
  • AICPA
  • Alibaba Cloud
  • Amazon
  • AMP
  • API
  • APICS
  • APM
  • APMG-International
  • Appian
  • Apple
  • ASIS
  • ASQ
  • ATLASSIAN
  • Automation Anywhere
  • Avaya
  • AVIXA
  • Axis
  • BCS
  • BICSI
  • Blue Prism
  • Broadcom
  • CAA Global
  • CFA
  • CheckPoint
  • CII
  • CIMA
  • CIPS
  • Cisco
  • Citrix
  • CIW
  • Cloud Security Alliance
  • Cloudera
  • CompTIA
  • Construction Specifications Institute
  • Copado
  • CrowdStrike
  • CSI
  • CWNP
  • CyberArk
  • DAMA
  • Databricks
  • EC-COUNCIL
  • ECCouncil
  • EMC
  • EPIC
  • Esri
  • EXIN
  • F5
  • Facebook
  • Fitness
  • Fortinet
  • GAQM
  • GARP
  • Genesys
  • GIAC
  • Google
  • Guidewire
  • H3C
  • Hitachi
  • HP
  • HRCI
  • Huawei
  • IAPP
  • IBM
  • IFSE Institute
  • IIA
  • IMA
  • Infor
  • IOFM
  • ISACA
  • ISC
  • ISQI
  • ISTQB
  • ITIL
  • Juniper
  • Linux Foundation
  • Lpi
  • Medical Tests
  • Microsoft
  • MongoDB
  • MSP-Foundation
  • NACE
  • NASM
  • National Payroll Institute
  • NCLEX
  • Network Appliance
  • Nokia
  • Nursing
  • Nutanix
  • NVIDIA
  • Okta
  • OMSB
  • Oracle
  • Palo Alto Networks
  • PCI
  • PECB
  • Pegasystems
  • PMI
  • PRINCE2
  • Proofpoint
  • Psychiatric Rehabilitation Association
  • Python Institute
  • Qlik
  • RCEM
  • RedHat
  • RUCKUS
  • Salesforce
  • SAP
  • SASInstitute
  • Scrum
  • ServiceNow
  • SHRM
  • Sitecore
  • Slack
  • Snowflake
  • SolarWinds
  • Splunk
  • Supermicro
  • Symantec
  • Tableau
  • The Institutes
  • The Open Group
  • UiPath
  • Uncategorized
  • USGBC
  • Veeam
  • VMware
  • WGU

Recent Comments

    Copyright © 2022 Prepaway Exam Dumps. DMCA Privacy Policy Contact US